WF 5218 Battery Monitoring and Balancing Node
The WF 5218 is a 12‑channel battery monitoring and balancing node for accurate cell measurement in series‑connected battery modules or packs. Each channel integrates a high‑voltage multiplexer, precision ADC, and a passive balancing resistor. The module also includes inputs for resistive temperature sensors.
A 1600 VDC double‑insulation barrier isolates the battery domain from the communication interface, providing highest personal safety in high‑voltage applications.
Multiple WF 5218 units can be connected in series and interfaced through the WF 5220 Gateway (USB) or the WF 5221 Gateway (EtherCAT). Both interfaces support open standards for easy software integration in common programming languages such as C, Python, C#, and LabVIEW.
$ 540.00
Quote request for WF 5218 Battery Monitoring and Balancing Node
Downloads & Information
Downloads
Data sheet
Application areas
- R&D battery‑stack monitoring
- Laboratory testing and prototyping
- Off‑line balancing
- BMS for energy‑storage system
- Second‑life evaluation of EV battery
- Battery state‑of‑health assessment
- EV battery service‑center diagnostics
Specifications
Analog Input Characteristics
- Number of channels: 12
- Measurement range Cn to Cn-1: 0 to 5 V
- Measurement resolution: 0.1 mV
- Measurement error: ± x mV typical
- Max sampling rate: 66 Hz
- Input leakage current: 10 nA typ @standby and 1uA@measure
- Bulit in balancing resistor: 150 Ω
Temperature input Characteristics
- Number of channels: 3
- Measurement resolution: 0.1 mV
- Measurement error: ± x mV typical
- Max sampling rate: 66 Hz
Power supply
- V+ to V- Supply Voltage: 5-75 V (11-55 V for full meas. accuracy)
- V+ Current@sleep: 6 uA
- V+ Current@measurement: 16 mA
- Max samling rate: 66 Hz
Isolation Voltages (rated working voltage)
- Channel to channel: None
- Channel to Link, Continuous: 1 600 V Double Insulation
- Link In to Link Out, Continuous: 80 V Double Insulation
Environmental
- Operating temperature: -20°C to 60°C
- Storage temperature: -20°C to 80°C
- Indoor / Outdoor: Indoor use only
Mechanical
- Size (w x d x h): 137.54 x 63.32 x 31.00 mm
- Weight: 128 g
Features
- 12‑channel cell‑voltage measurement (0–5 V per cell)
- Integrated passive balancing on all channels
- Inputs for resistive temperature sensors
- 1600 VDC double‑insulation barrier for highest personal safety
- High‑resolution ADC with 0.1 mV resolution
- ±x mV typical measurement accuracy
- Daisy‑chain of up to 16 nodes per gateway
- Compatible with WF 5220 (USB) and WF 5221 (EtherCAT)
- Open communication interfaces for easy software integration
Shipping information
– Product Net Weight: 128 g
– Country of Origin: Sweden (SE)
– Harmonized System (HS) Code: xxxxxx
– Combined Nomenclature (CN) Code: xxxxxx.xx
– TARIC Code: xxxxxx.xx.xx